Fly SHT-42 CAN bus Termination
Edit me

SHT-42 CAN bus termination jumpers

Fly SHT-42 CAN bus termination

  • CAN bus must have two 120 ohm resistors. One at each end of the bus.
  • Failure to correctly terminate the CAN bus cause to communication issues and instability.
  • No matter how many USB devices you connect on a singe bus only enable one 120 ohm resistor at each end of the bus. There is no need to add a resistor to every CAN device
  • The resistance between CAN H and CAN L measured with the system powerd off should be 60 ohms with all CAN devices connected.
  • If you are using a UTOC to connect to the Fly SHT-42, you will only need to connect the Fly SHT-42s two jumper caps. The UTOC 120 ohm resistor is not jumpered and always enabled.
Fly SHT-42 120R jumpers
Fly SHT-42 120R jumpers
  • The Fly SHT-42 has an on-board 120 ohm resistor that is enabled by installing two jumpers.